BT 21CN Table of Results
21CN Testing Programme
BT have provided test facilities to telephony equipment manufacturers, including social alarm equipment manufacturers, so that the equipment can be tested on both a simulated and ‘live’ representation of the 21CN network, in order to demonstrate their level of compatibility.
The testing focuses’ on the main changes of 21CN:
- Balanced ringing – this can affect older equipment in such a way that the equipment may no longer recognise the incoming ringing signal.
- Line lengths – the maximum length of telephone lines from the exchange will increase from 6km to 10km, and may result in lower speech volumes and potentially unreliable communications.
- Reduced line current – the telephone line current available for equipment in the home has been reduced from 40mA to 25mA – performance of receiver and hands free may be reduced.
- End to end delays – the new network will have a higher nominal end to end delay and this is likely to increase over time as new digital services are added and the network load increases; this will cause some protocols to operate unreliably and may result in alarm calls not getting through to the alarm receiving centre.
BT categorise the outcome of this testing as follows:-
Pass – equipment functionality not affected by 21CN
Pass 1 – user perception affected (e.g. ringing tone different)
Pass 2 – user operation affected (e.g. user has to switch from pulse to tone dialling)
Partial fail – functionality lost. The reliability of the equipment is reduced and will mean that the end user of the equipment could be at increased risk, if the equipment is life critical in nature replacement or upgrade must be considered
Fail – equipment not advised to be used on 21CNTable of results for Chubb Community Care
Manufacturer Product Type Result Chubb UK IntelliLink Classic 868 Mk1 (1) Dispersed Alarm Unit Pass Chubb UK IntelliLink Executive 868 Mk1 (2) Dispersed Alarm Unit Pass Chubb UK IntelliLink Classic 869 Mk1 (3) Dispersed Alarm Unit Pass Chubb UK IntelliLink Executive 869 Mk1 Dispersed Alarm Unit Pass Chubb UK IntelliLink Classic T Mk1 Dispersed Alarm Unit Pass Chubb UK IntelliLink Executive 869 Mk2 Dispersed Alarm Unit Pass Chubb Saturn Monitoring Equipment (Post Oct 07 or prior Sept 07 with upgraded line interface cards) Control Pass Chubb Concept Group Pass Chubb Concept Plus Group Pass Chubb Concept RS Group Pass Attendo Systems Advantage Group Pass Attendo Systems Horizon 2 Dispersed Alarm Unit Pass Attendo Systems Horizon Plus Dispersed Alarm Unit Pass Shorrock Elite Dispersed Alarm Unit Pass Shorrock Excel Dispersed Alarm Unit Pass Shorrock Premicell Dispersed Alarm Unit Pass Shorrock Premier Dispersed Alarm Unit Pass Shorrock Eclipse Dispersed Alarm Unit Pass Cass/Davis Com 1 & 2 Group Pass Cass/Davis PM2000+ Group Pass - 1) UK IntelliLink Classic 868 Mk1 (Iss 2r3, S/N UC10921 on)
- 2) UK IntelliLink Executive 868 Mk1 (Iss 2r3, S/N UE04576 on)
- 3) UK IntelliLink Classic 869 Mk1 (Iss 1r1, S/N UCV01711 on)
Manufacturer Product Type Result Notes Chubb UK IntelliLink Classic 868 Mk1 Dispersed Alarm Unit Partial Fail 1 Chubb UK IntelliLink Executive 868 Mk1 Dispersed Alarm Unit Partial Fail 2 Chubb UK IntelliLink Classic 869 Mk1 Dispersed Alarm Unit Partial Fail 3 Chubb Saturn Monitoring Equipment (Prior to Sept 07) Control Partial Fail 4 Shorrock Eclipse (only serial M020470 to M024092) Dispersed Alarm Unit Partial Fail 5 Wolsey CareCall Group Partial Fail 6 Wolsey Domus Group Partial Fail 6 Wolsey Omega Group Partial Fail 6 Wolsey Herald Group Partial Fail 6 Cass/Davis Respond Group Partial Fail 7 Cass/Davis Com 2000 Group Partial Fail 7 Cass/Davis Com D Group Partial Fail 7 Cass/Davis Erricare Group Partial Fail 7 Cass/Davis Talisman Dispersed Alarm Unit Partial Fail 7 Cass/Davis Call Link Dispersed Alarm Unit Partial Fail 7 - 1) Saturn Monitoring Equipment – Prior to September 07 an upgrade is required to a new line interface.
- 2) UK IntelliLink Classic 868 Mk1 (only these serials, up to and including Iss 2r2, S/N UC10920) – Recommend return for a free software upgrade or replace.
- 3) UK IntelliLink Executive 868 Mk1 (only these serials, up to and including Iss 2r2, S/N UE04575) – Recommend return for a free software upgrade or replace.
- 4) UK IntelliLink Classic 869 Mk1 (only these serials, up to and including Iss 1r0, S/N UCV01710) – Recommend return for a free software upgrade or replace.
- 5) Eclipse Dispersed Alarm Unit (Serial Numbers M020470 to M024092 only) – Recommend check your Eclipse units and either return for a free upgrade or replace.
- 6) Recommend a technical audit review and replacement if necessary.
- 7) Recommend a technical audit review and replacement if necessary.
Manufacturer Product Type Result Raitel Viking (1) Group Fail Raitel Independence Dispersed Alarm Unit Fail Telefusion Wardecom Group Fail Telefusion Wardecom 2 Group Fail Telefusion Wardecom 3 Group Fail Shorrock Care Link Dispersed Alarm Unit Fail Cass/Davis Unidial 1 Dispersed Alarm Unit Fail Cass/Davis Unidial 2 Dispersed Alarm Unit Fail Cass/Davis Unidial 3 Dispersed Alarm Unit Fail - 1) The orginal FSK dialler will fail on the Viking system but this can be upgraded to a new Line Interface Card.
- For Critical Fail equipment (with the exception of Viking) we recommend replacement of these products.
For all of the above, we recommend that you contact the BT21 Helpline on 01254 688 548 for more information.